Technical Parameter
Model | Voltage(V) | Flow(m3/hr) | Fan Diameter(mm) | Power(kw) | Dimension (mm) | Net Weight(kg) | Work Weight(kg) | Piping | ||||
Height | Outer Diameter | Inlet | Drainage | Sewage Disposal | Water Port | |||||||
LXT-CT3T | 380 | 3 | 300 | 0.038 | 1200 | 650 | 35 | 85 | 25 | 25 | 25 | 15 |
LXT-CT6T | 6 | 585 | 0.18-6 | 1520 | 930 | 53 | 133 | 40 | 40 | 25 | 15 | |
LXT-CT8T | 8 | 600 | 0.18-6 | 1620 | 930 | 56 | 139 | 40 | 40 | 25 | 15 | |
LXT-CT10T | 10 | 600 | 0.18-6 | 1780 | 960 | 75 | 200 | 40 | 40 | 25 | 15 | |
LXT-CT12T | 12 | 600 | 0.18-6 | 1820 | 1040 | 80 | 220 | 50 | 50 | 25 | 15 | |
LXT-CT16T | 16 | 760 | 0.37-6 | 1900 | 1120 | 85 | 300 | 50 | 50 | 25 | 15 | |
LXT-CT20T | 20 | 760 | 0.37-6 | 1900 | 1250 | 110 | 320 | 50 | 50 | 25 | 15 | |
LXT-CT25T | 25 | 760 | 0.37-6 | 2010 | 1420 | 140 | 340 | 50 | 50 | 25 | 15 | |
LXT-CT30T | 30 | 770 | 0.37-6 | 2100 | 1420 | 160 | 350 | 50 | 50 | 25 | 15 | |
LXT-CT40T | 40 | 885 | 1.1-8 | 2120 | 1650 | 165 | 369 | 80 | 80 | 25 | 15 | |
LXT-CT50T | 50 | 885 | 1.1-8 | 2200 | 1850 | 185 | 433 | 80 | 80 | 25 | 15 | |
LXT-CT60T | 60 | 885 | 1.1-8 | 2450 | 1870 | 220 | 730 | 80 | 80 | 25 | 15 | |
LXT-CT70T | 70 | 1000 | 1.1-8 | 2550 | 2020 | 368 | 753 | 100 | 100 | 40 | 20 | |
LXT-CT80T | 80 | 1190 | 1.5-8 | 2680 | 2350 | 460 | 1023 | 100 | 100 | 40 | 20 | |
LXT-CT90T | 90 | 1470 | 2.2-12 | 2760 | 2520 | 650 | 1080 | 100 | 100 | 40 | 20 | |
LXT-CT100T | 100 | 1470 | 2.2-12 | 2870 | 2900 | 695 | 1130 | 125 | 125 | 40 | 20 | |
LXT-CT150T | 150 | 1800 | 4-12 | 3450 | 3300 | 1015 | 2035 | 125 | 125 | 40 | 20 | |
LXT-CT175T | 175 | 1800 | 4-12 | 3800 | 3600 | 1310 | 2540 | 150 | 150 | 50 | 20 | |
LXT-CT200T | 200 | 1800 | 4-12 | 4000 | 4000 | 1613 | 3317 | 150 | 150 | 50 | 25 | |
LXT-CT250T | 250 | 2400 | 5.5 | 4350 | 4500 | 2121 | 3876 | 200 | 200 | 50 | 25 | |
LXT-CT300T | 300 | 3000 | 7.5 | 4600 | 4900 | 2235 | 3990 | 200 | 200 | 50 | 25 | |
Specifications are subject to change without notice. |
Product Details
Installation Structure
Cooling tower installation structure 1:
The water pump pumps the water in the cooling tower to the sealing equipment. Generally, the sealed pipeline has pressure to automatically press the water back to the cooling tower
(If the pipeline is long and there are many bends, it is also recommended that the pump model be equipped with a large one or the return water be installed with another pump)
(If the opposite equipment is an open water tank, the return water must be equipped with another pump)
Cooling tower installation structure 2:
The cooling tower is slightly raised or supported on the pool, and flows to the pool naturally. The pump draws the water from the pool to the sealed equipment.
Because the equipment is sealed, the return water naturally has pressure (If the opposite equipment is an open water tank, the return water must be equipped with another pump)